1.
Materials (Basel) ; 12(24)2019 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-31835752

RESUMO

Scanning magnetic microscopy is a tool that has been used to map magnetic fields with good spatial resolution and field sensitivity. This technology has great advantages over other instruments; for example, its operation does not require cryogenic technology, which reduces its operational cost and complexity. Here, we presented a spatial domain technique based on an equivalent layer approach for processing the data set produced by magnetic microscopy. This approach estimated a magnetic moment distribution over a fictitious layer composed by a set of dipoles located below the observation plane. For this purpose, we formulated a linear inverse problem for calculating the magnetic vector and its amplitude. Vector field maps are valuable tools for the magnetic interpretation of samples with a high spatial variability of magnetization. These maps could provide comprehensive information regarding the spatial distribution of magnetic carriers. In addition, this approach might be useful for characterizing isolated areas over samples or investigating the spatial magnetization distribution of bulk samples at the micro and millimeter scales. This technique could be useful for many applications that require samples that need to be mapped without a magnetic field at room temperature, including rock magnetism.

2.
Sensors (Basel) ; 19(7)2019 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-30959784

RESUMO

We improved a magnetic scanning microscope for measuring the magnetic properties of minerals in thin sections of geological samples at submillimeter scales. The microscope is comprised of a 200 µm diameter Hall sensor that is located at a distance of 142 µm from the sample; an electromagnet capable of applying up to 500 mT DC magnetic fields to the sample over a 40 mm diameter region; a second Hall sensor arranged in a gradiometric configuration to cancel the background signal applied by the electromagnet and reduce the overall noise in the system; a custom-designed electronics system to bias the sensors and allow adjustments to the background signal cancelation; and a scanning XY stage with micrometer resolution. Our system achieves a spatial resolution of 200 µm with a noise at 6.0 Hz of 300 nTrms/(Hz)1/2 in an unshielded environment. The magnetic moment sensitivity is 1.3 × 10-11 Am². We successfully measured the representative magnetization of a geological sample using an alternative model that takes the sample geometry into account and identified different micrometric characteristics in the sample slice.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...